Div. B › Part 12 › 12.2 › 12.2.1 — Energy Efficiency Design

12.2.1.1 — Energy Efficiency Design Before January 1, 2017

Copied!
(1) This Article applies to construction for which a permit has been applied for before January 1, 2017.
(2) Except as provided in Sentences (3) and (4), the energy efficiency of all buildings shall conform to Division 1 and Division 2 or 4 of MMA Supplementary Standard SB-10, “Energy Efficiency Requirements”.
(3) Except as provided in Sentence (4), the energy efficiency of a building or part of a building of residential occupancy that is within the scope of Part 9 and is intended for occupancy on a continuing basis during the winter months shall,
(a) meet the performance level that is equal to a rating of 80 or more when evaluated in accordance with NRCan, “EnerGuide for New Houses: Administrative and Technical Procedures”, or
(b) conform to Chapters 1 and 2 of MMA Supplementary Standard SB-12, “Energy Efficiency for Housing”.
(4) This Article does not apply to,
(a) a farm building,
(b) a building that does not use electrical power or fossil fuel,
(c) a manufactured building described in Article 9.1.1.9., or
(d) a seasonal recreational building described in Section 9.36. or 9.38.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.