(1) Where the performance level of an existing building is reduced under Clause 11.4.2.3. (1) (a), (b), (c), (d), (e) or (g), additional upgrading shall be required in conformance with Table 11.4.3.4.A. and so that the construction index of the building is increased to at least equal the hazard index of the new major occupancy that the building is to support.
(2) A building or part of the building subject to a change of major occupancy shall conform to the requirements of Subsection 3.2.6., Sections 3.7., 3.11., 3.12., Sentences 6.2.2.1. (2), 6.2.3.9. (1) and 6.2.4.7. (10), Subsections 9.5.1. and 9.5.3. to 9.5.10., Section 9.7., Subsection 9.10.17., Sections 9.31. and 9.32., and Subsections 9.34.1. to 9.34.3. as they apply to the new major occupancy that the building or part of the building is to support.
(3) Where the performance level of an existing building is reduced under Sentence 11.4.2.3. (3), the building shall be evaluated, and the early warning and evacuation systems shall be upgraded, in conformance with the applicable requirements of Table 11.4.3.3.
(4) Where the performance level of an existing building is reduced under Sentence 11.4.2.3. (4), upgrading of the fire separations shall be required in conformance with the applicable requirements of Article 3.1.3.1. and Table 11.4.3.4.B.
(5) Where the performance level is reduced under Sentence 11.4.2.3. (5), the requirement for the building to be of noncombustible construction or to be constructed in accordance with Article 3.2.2.43A. or 3.2.2.50A. is satisfied if the building is sprinklered.
(6) Where the performance level is reduced under Sentence 11.4.2.3. (6), the storey subject to the change shall be sprinklered.
(7) Where the performance level of an existing building is reduced under Clause 11.4.2.3. (1) (f), the following requirements apply:
(a) the retirement home shall be sprinklered,
(b) a voice communication system conforming to Article 3.2.4.23. shall be provided in the building, and
(c) doors to suites and sleeping rooms not within suites in the retirement home, other than doors leading directly to the exterior, shall be equipped with self-closing devices.