Div. B › Part 5 › 5.3 › 5.3.1 — Thermal Resistance of Assemblies

5.3.1.2 — Properties to Resist Heat Transfer or Dissipate Heat

Copied!
(1) Materials and components installed to provide the required resistance to heat transfer or the means implemented to dissipate heat shall,
(a) provide sufficient resistance or dissipation,
(i) to minimize surface condensation on the warm side of the component or assembly,
(ii) in conjunction with other materials and components in the assembly, to minimize condensation within the component or assembly,
(iii) in conjunction with systems installed for space conditioning, to meet the interior design thermal conditions for the intended occupancy, and
(iv) to minimize ice damming on sloped roofs, and
(b) take into account the conditions on either side of the environmental separator.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.