(1) Waterproofing materials, components, assemblies or systems installed to provide the required protection shall form a continuous and impervious barrier to the ingress of ground water and be capable of accommodating,
(a) imperfections, construction joints, control joints and expansion joints,
(b) junctions between different building assemblies, and
(c) elements penetrating building assemblies.