Div. B › Part 5 › 5.7 › 5.7.3 — Protection from Ground Water

5.7.3.3 — Waterproofing

Copied!
(1) Waterproofing materials, components, assemblies or systems installed to provide the required protection shall form a continuous and impervious barrier to the ingress of ground water and be capable of accommodating,
(a) imperfections, construction joints, control joints and expansion joints,
(b) junctions between different building assemblies, and
(c) elements penetrating building assemblies.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.