Div. B › Part 5 › 5.8 › 5.8.1 — Protection from Airborne Noise

5.8.1.2 — Determination of Sound Transmission Ratings

Copied!
(1) The STC ratings of separating assemblies shall be determined in accordance with ASTM E413, “Classification for Rating Sound Insulation”, using the results from measurements carried out in accordance with ASTM E90, “Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements”.
(2) The ASTC ratings of separating assemblies and adjoining construction shall be,
(a) determined in accordance ASTM E413, “Classification for Rating Sound Insulation”, using the results from measurements carried out in accordance with ASTM E336, “Measurement of Airborne Sound Attenuation Between Rooms in Buildings”, or
(b) calculated in accordance with,
(i) the detailed method described in Article 5.8.1.4., or
(ii) the simplified method described in Article 5.8.1.5.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.