Div. B › Part 6 › 6.2 › 6.2.10 — Refrigerating Systems and Equipment for Air-Conditioning

6.2.10.1 — Cooling Units

Copied!
(1) Where a cooling unit is combined with a fuel-fired furnace in the same duct system, the cooling unit shall be installed,
(a) in parallel with the heating furnace,
(b) upstream of the furnace, provided the furnace is designed for such application, or
(c) downstream of the furnace, provided the cooling unit is designed to prevent excessive temperature or pressure in the refrigeration system.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.