Div. B › Part 6 › 6.3 › 6.3.1 — General

6.3.1.2 — Masonry or Concrete Chimneys

Copied!
(1) Rectangular masonry or concrete chimneys not more than 12 m in height shall conform to Part 9 if they serve,
(a) appliances with a combined total rated heat output of 120 kW or less, or
(b) fireplaces.
(2) Masonry or concrete chimneys other than those described in Sentence (1) shall be designed and installed in conformance with the appropriate requirements in NFPA 211, “Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances”.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.