Div. B › Part 8 › 8.6 › 8.6.2 — Treatment Units

8.6.2.1 — Septic Tank Systems

Copied!
(1) An effluent filter shall be installed in the outlet flow path of every septic tank that discharges effluent to a leaching bed.
(2) The septic tank effluent filter required by Sentence (1) shall,
(a) conform to the requirements of NSF/ANSI 46, “Evaluation of Components and Devices Used in Wastewater Treatment Systems”,
(b) be sized to filter particles of 1.6 mm,
(c) have a minimum area of 550 cm2, and
(d) be installed in accordance with the manufacturer’s recommendations.
(3) A secured access opening to allow for regular maintenance of the effluent filter shall be provided at the ground surface.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.