Div. B › Part 4 › 4.1 › 4.1.5 — Live Loads Due to Use and Occupancy

4.1.5.5 — Loads on Exterior Areas

Copied!
(1) Exterior areas accessible to vehicular traffic shall be designed for their intended use, including the weight of firefighting equipment, but not for less than the snow and rain loads prescribed in Subsection 4.1.6.
(2) Except as provided in Sentences (3) and (4), roofs shall be designed for the uniform live loads specified in Table 4.1.5.3., the concentrated live loads listed in Table 4.1.5.9., or the snow and rain loads prescribed in Subsection 4.1.6., whichever produces the most critical effects in the members concerned.
(3) Exterior areas accessible to pedestrian traffic, but not vehicular traffic, shall be designed for their intended use, but not for less than the greater of,
(a) the live load prescribed for assembly areas in Table 4.1.5.3., or
(b) the snow and rain loads prescribed in Subsection 4.1.6.
(4) Roof parking decks shall be designed for the uniformly distributed live loads specified in Table 4.1.5.3., the concentrated live loads listed in Table 4.1.5.9., or the roof snow load, whichever produces the most critical effect in the members concerned.
Tables & Figures referenced
Table 4.1.5.3 : Specified Uniformly Distributed Live Loads on an Area of Floor or Roof : Forming Part of Sentence 4.1.5.3.(1)
Loading Table 4.1.5.3…
Table 4.1.5.9 : Specified Concentrated Live Loads on an Area of Floor or Roof : Forming Part of Sentence 4.1.5.9.(1)
Loading Table 4.1.5.9…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.