7.2.10.14 — Vent Pipe Flashing

Copied!
(1) Flashing fabricated on site for vent pipes shall be fabricated from,
(a) copper sheet at least 0.33 mm thick,
(b) aluminum sheet at least 0.48 mm thick,
(c) alloyed zinc sheet at least 0.35 mm thick,
(d) lead sheet at least 1.73 mm thick,
(e) galvanized steel sheet at least 0.33 mm thick, or
(f) polychloroprene (neoprene) at least 2.89 mm thick.
(2) Prefabricated flashing for vent pipes shall be certified to CSA B272, “Prefabricated Self-Sealing Roof Vent Flashings”.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.