Div. B › Part 7 › 7.4 › 7.4.5 — Traps

7.4.5.2 — Traps for Storm Drainage Systems

Copied!
(1) Where a storm drainage system is connected to a public combined sewer, a trap shall be installed between any opening in the system and the drain or sewer, except that no trap is required if the opening is the upper end of a leader that terminates,
(a) at a roof that is used only for weather protection,
(b) not less than 1 000 mm above or not less than 3.5 m in any other direction from any air inlet, openable window or door, and
(c) not less than 1 800 mm from a property line.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.