Div. B › Part 7 › 7.5 › 7.5.4 — Vent Pipes for Soil or Waste Stacks

7.5.4.4 — Offset Relief Vents

Copied!
(1) A soil or waste stack that has a nominally horizontal offset more than 1 500 mm long and above which the upper vertical portion of the stack passes through more than 2 storeys and receives a hydraulic load of more than 100 fixture units shall be vented by an offset relief vent connected to the vertical section immediately above the offset, and by another offset relief vent,
(a) connected to the lower vertical section at or above the highest soil or waste pipe connection, or
(b) extended as a vertical continuation of the lower section.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.