(1) A building sewer intended to serve a mobile home shall,
(a) be not less than 4 in. in size,
(b) be terminated above ground,
(c) be provided with,
(i) a tamperproof terminal connection that is capable of being repeatedly connected, disconnected and sealed,
(ii) a protective concrete pad, and
(iii) a means to protect it from frost heave, and
(d) be designed and constructed in accordance with good engineering practice.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.