Div. B › Part 7 › 7.5 › 7.5.7 — Minimum Size of Vent Pipes

7.5.7.3 — Additional Circuit Vents and Relief Vents

Copied!
(1) Except as provided in Article 7.5.7.1. and in Sentence 7.5.3.1. (7), the minimum size of an additional circuit vent or relief vent installed in conjunction with a circuit vent is permitted to be one size smaller than the required size of the circuit vent, but need not be larger than 2 in.
(2) The size of the soil or waste pipe acting as a relief vent in accordance with Sentence 7.5.3.1. (4) shall be in conformance with Table 7.4.10.6., 7.4.10.7. or 7.5.8.1. or Article 7.5.7.1., whichever size is the largest considering the hydraulic load drained into the soil or waste pipe.
Tables & Figures referenced
Table 7.4.10.6 : Maximum Permitted Hydraulic Load Drained to Soil or Waste Stack : Forming Part of Sentence 7.4.10.6.(1)
Loading Table 7.4.10.6…
Table 7.4.10.7 : Maximum Permitted Hydraulic Load Drained to a Branch : Forming Part of Sentence 7.4.10.7.(1)
Loading Table 7.4.10.7…
Table 7.5.8.1 : Maximum Permitted Hydraulic Loads Drained to a Wet Vent : Forming Part of Articles 7.5.2.1. and 7.5.8.1.
Loading Table 7.5.8.1…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.