Div. B › Part 7 › 7.2 › 7.2.2 — Fixtures

7.2.2.3 — Showers

Copied!
(1) Shower receptors shall be constructed and arranged so that water cannot leak through the walls or floor.
(2) Not more than six shower heads shall be served by a single shower drain.
(3) Where two or more shower heads are served by a shower drain, the floor shall be sloped and the drain located so that water from one head cannot flow over the area that serves another head.
(4) Except for column showers, when a battery of shower heads is installed, the horizontal distance between two adjacent shower heads shall be at least 750 mm.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.