Div. B › Part 7 › 7.4 › 7.4.7 — Cleanouts

7.4.7.3 — Manholes

Copied!
(1) A manhole including the cover shall be designed to support all loads imposed upon it.
(2) A manhole shall be provided with,
(a) a cover which shall provide an airtight seal if located within a building,
(b) a rigid ladder of a corrosion-resistant material where the depth exceeds 1 000 mm, and
(c) a vent to the exterior if the manhole is located within a building.
(3) A manhole shall have a minimum horizontal dimension of 1 200 mm, except that the top 1 500 mm may be tapered from 1 200 mm down to a minimum of 600 mm at the top.
(4) A manhole in a sanitary drainage system shall be channelled to direct the flow of effluent.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.