Div. B › Part 7 › 7.4 › 7.4.10 — Hydraulic Loads

7.4.10.8 — Hydraulic Loads on Sanitary Horizontal Drain

Copied!
(1) Except as permitted by Article 7.4.10.7., the hydraulic load that is drained to a horizontal sanitary drainage pipe shall conform to Table 7.4.10.8., based on the size and slope.
(2) Horizontal sanitary drainage pipe shall be designed to carry no more than 65% of its full capacity.
Tables & Figures referenced
Table 7.4.10.8 : Maximum Permitted Hydraulic Load Drained to a Horizontal Sanitary Drainage Pipe : Forming Part of Sentences 7.4.10.6.(2) and 7.4.10.8.(1)
Loading Table 7.4.10.8…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.