Div. B › Part 7 › 7.5 › 7.5.8 — Sizing of Vent Pipes

7.5.8.1 — Hydraulic Loads Draining to Wet Vents

Copied!
(1) The hydraulic load that drains to a wet vent shall conform to Table 7.5.8.1.
(2) When determining the size of a wet vent, the hydraulic load from the most downstream fixture or symmetrically connected fixtures shall not be included.
Tables & Figures referenced
Table 7.5.8.1 : Maximum Permitted Hydraulic Loads Drained to a Wet Vent : Forming Part of Articles 7.5.2.1. and 7.5.8.1.
Loading Table 7.5.8.1…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.