3.10.2.5 — Exit Requirements

Copied!
(1) Except as provided in Sentences (2) and (3), the requirements in Section 3.4. shall apply.
(2) The clear width of an exit stair shall be not less than 1 100 mm.
(3) Exit doors from rental spaces are not required to swing on a vertical axis provided,
(a) the area of the rental space is not more than 50 m2, and
(b) the travel distance within the rental space is not more than 10 m.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.