Div. B › Part 3 › 3.9 › 3.9.3 — Application

3.9.3.2 — Spatial Separations

Copied!
(1) The requirements in Subsection 3.2.3. need not be provided between individual portable classrooms where the distance between the classrooms is 6 m or more.
(2) The requirements in Subsection 3.2.3. need not be provided between individual portable classrooms within a group where,
(a) the portable classrooms are in groups where,
(i) the distance between the classrooms is less than 6 m,
(ii) the number of classrooms in a group is not more than six, and
(iii) the distance between groups of classrooms is 12 m or more, or
(b) the portable classrooms are in groups where,
(i) the means of egress for each classroom within a group is by a common corridor or passageway,
(ii) the number of portable classrooms in a group is not more than six, and
(iii) the distance between groups of portable classrooms is 12 m or more.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.