Div. B › Part 3 › 3.16 › 3.16.1 — Scope

3.16.1.3 — Construction

Copied!
(1) All structural components of a shelf and rack storage system, including posts, beams, decks, walkways, connections and their supports such as concrete slabs and foundations, shall be designed in accordance with Part 4.
(2) Except as required by Sentence 3.16.3.2. (2), platform and walkway levels shall be of,
(a) solid construction consisting of steel plate or steel roof decking with a top substrate that forms a serviceable floor area, or
(b) open construction consisting of steel grating or open steel floor planking.
(3) Guards and toe-boards shall be provided in accordance with Articles 3.3.1.17. and 3.3.5.8.
(4) Every platform or walkway level shall be provided with fire extinguishers installed in conformance with the Fire Code made under the Fire Protection and Prevention Act, 1997.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.