Div. B › Part 3 › 3.4 › 3.4.7 — Fire Escapes

3.4.7.3 — Access to Fire Escapes

Copied!
(1) Access to fire escapes shall be from corridors through doors at floor level, except that access from a dwelling unit is permitted to be through a casement window having an unobstructed opening not less than 1 100 mm high by 550 mm wide with a sill height of not more than 900 mm above the inside floor.
(2) The clear area of a fire escape balcony onto which a door opens, shall be not less than 1 m2.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.