Div. B › Part 3 › 3.3 › 3.3.4 — Residential Occupancy

3.3.4.8 — Protection of Openable Windows

Copied!
(1) Except as provided by Sentence (2), openable windows in suites of residential occupancy shall be protected by,
(a) a guard with a minimum height of 1 070 mm constructed in accordance with Article 3.3.1.17., or
(b) a mechanism capable of controlling the free swinging or sliding of the openable part of the window so as to limit any clear unobstructed opening to a size that will prevent the passage of a sphere having a diameter more than 100 mm.
(2) Windows need not be protected in accordance with Sentence (1) where,
(a) the only opening having greater dimensions than those allowed by Clause (1) (b) is located higher than 1 070 mm above the finished floor, or
(b) the bottom edge of the openable portion of the window is located less than 1 800 mm above the floor or ground on the other side of the window.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.