Div. B › Part 3 › 3.14 › 3.14.2 — Air-Supported Structures

3.14.2.2 — General

Copied!
(1) Air-supported structures shall not be used for Groups B, C or Group F, Division 1 major occupancies or for classrooms.
(2) Except where no fire separation is required between major occupancies, air-supported structures shall contain not more than one major occupancy.
(3) Except as provided in Sentence (5), air-supported structures are exempt from complying with Articles 3.2.2.20. to 3.2.2.83., except for maximum building size.
(4) Air-supported structures may be designed with interior walls, mezzanines, or similar construction.
(5) Interior construction contained within air-supported structures must meet the construction requirements of Articles 3.2.2.20. to 3.2.2.83.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.