(1) Except as provided in Sentence (2), a sleeping area in a Group B occupancy shall provide not less than 4.7 m2 per person in a room having,
(a) an area not less than 7 m2,
(b) a horizontal dimension not less than 2 000 mm, and
(c) a ceiling height not less than 2 300 mm.
(2) Sleeping rooms for residents in long-term care homes shall have, exclusive of space provided for washrooms and for built-in or portable clothes closets, a floor space not less than,
(a) 10.22 m2 in a single-bed unit,
(b) 16.72 m2 in a two-bed unit,
(c) 25.08 m2 in a three-bed unit, and
(d) 29.73 m2 in a four-bed unit.
(3) A child care facility shall provide sleeping accommodation having not less than 0.93 m2 of floor surface area for each child with not less than 2 300 mm ceiling height over the entire room area.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.