Div. B › Part 3 › 3.13 › 3.13.8 — Barrier-Free Design

3.13.8.4 — Emergency Operation of Elevators

Copied!
(1) Manual emergency recall operation shall be provided for all elevators.
(2) Key-operated switches for emergency recall described in Sentence (1) shall be provided and shall be located on the outside of each elevator shaft at the level of the fare-paid area control.
(3) In-car emergency service switches shall be provided in all elevator cars.
(4) Keys to operate the switches required in Sentences (2) and (3) shall be located at,
(a) the annunciator required in Clause 3.13.5.5. (1) (a), and
(b) the collector’s booth designated in Clause 3.13.5.5. (1) (b).
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.