Div. B › Part 3 › 3.3 › 3.3.1 — All Floor Areas

3.3.1.15 — Tapered Treads in a Curved Flight

Copied!
(1) Flights shall consist solely of,
(a) straight flights, or
(b) curved flights complying with Sentence (2).
(2) Tapered treads in a curved flight that is not required as an exit shall have,
(a) a minimum run of 150 mm,
(b) a run not less than 280 mm when measured at a point 300 mm from the centre line of the inside handrail, and
(c) a riser conforming to Sentence 3.4.6.8. (2).
(3) Tapered treads shall have a consistent angle and uniform run and rise dimensions in accordance with the construction tolerances described in Article 3.4.6.8. when measured at a point 300 mm from the centre line of the inside handrail.
(4) All tapered treads within a flight shall turn in the same direction.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.