(1) Flights shall consist solely of,
(a) straight flights, or
(b) curved flights complying with Sentence (2).
(2) Tapered treads in a curved flight that is not required as an exit shall have,
(a) a minimum run of 150 mm,
(b) a run not less than 280 mm when measured at a point 300 mm from the centre line of the inside handrail, and
(c) a riser conforming to Sentence 3.4.6.8. (2).
(3) Tapered treads shall have a consistent angle and uniform run and rise dimensions in accordance with the construction tolerances described in Article 3.4.6.8. when measured at a point 300 mm from the centre line of the inside handrail.
(4) All tapered treads within a flight shall turn in the same direction.