Div. B › Part 3 › 3.10 › 3.10.4 — Additional Requirements for 1 Storey Buildings

3.10.4.3 — Spatial Separations

Copied!
(1) Except as provided in Sentences (2) to (4), the requirements in Subsection 3.2.3. shall apply.
(2) Where the building area conforms to Clause 3.10.4.2. (1) (b), the limiting distance requirements shall not apply between individual buildings.
(3) Where the building area conforms to Clause 3.10.4.2. (1) (c),
(a) the limiting distance requirements shall apply between each group of buildings, but not between individual buildings within a group, and
(b) the distance between each group of buildings shall be not less than 9 m.
(4) The distance between individual buildings within a group shall be not less than 6 m.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.