(1) If a demountable stage is intended for limited public occupancy, a barrier-free path of travel conforming to Articles 3.8.1.3. and 3.8.3.4. shall be provided to and throughout at least one platform of the demountable stage.
(1) Except as required in Sentence (4) and except as permitted in Subsection 3.8.3., every barrier-free path of travel shall provide an unobstructed width of at least 1 100 mm for the passage of wheelchairs. (2) Interior and exterior walking surfaces that are within a barrier-free path of travel shall,
(a) have no opening that will permit the passage of a sphere more than 13 mm in diam,
(b) have any elongated openings oriented approximately perpendicular to the direction of travel,
(c) be stable, firm and slip-resistant,
(d) be bevelled at a maximum slope of 1 in 2 at changes in level not more than 13 mm, and
(e) be provided with sloped floors or ramps at changes in level more than 13 mm. (3) A barrier-free path of travel is permitted to include ramps, passenger elevators or other platform equipped passenger elevating devices to overcome a difference in level. (4) Every barrier-free path of travel less than 1 600 mm in width shall be provided with an unobstructed space not less than 1 800 mm in width and 1 800 mm in length located not more than 30 m apart. (5) Where the headroom of an area in a barrier-free path of travel is reduced to less than 1 980 mm, a guardrail or other barrier with its leading edge at or below 680 mm from the finished floor shall be provided. (6) A normally occupied floor area that is not required by Article 3.8.2.1. to have a barrier-free path of travel shall meet the following requirements:
(a) interior walking surfaces throughout the normally occupied floor area shall comply with Clauses (2)(a) to (e), and
(b) where the headroom of an area in a corridor or aisle in the normally occupied floor area is reduced to less than 1 980 mm, a guardrail or other barrier with its leading edge at or below 680 mm from the finished floor shall be provided.
(1) Ramps located in a barrier-free path of travel shall,
(a) have a minimum width of 900 mm between handrails,
(b) have a maximum gradient of 1 in 12,
(c) have a level area of at least 1 670 mm by 1 670 mm at the top and bottom of a ramp and where a door is located in a ramp, so that the level area extends at least 600 mm beyond the latch side of the door opening, except that where the door opens away from the ramp, the area extending beyond the latch side of the door opening may be reduced to 300 mm,
(d) have a level area at least 1 670 mm long and at least the same width as the ramp,
(i) at intervals of not more than 9 m along its length, and
(ii) where there is a change of 90° or more in the direction of the ramp,
(e) except as provided in Sentence (2), be equipped with handrails on both sides that shall,
(i) be continuously graspable along their entire length and have circular cross-section with an outside diameter not less than 30 mm and not more than 40 mm, or any non-circular shape with a graspable portion that has a perimeter not less than 100 mm and not more than 155 mm and whose largest cross-sectional dimension is not more than 57 mm,
(ii) be not less than 865 mm and not more than 965 mm high, measured vertically from the surface of the ramp, except that handrails not meeting these requirements are permitted provided they are installed in addition to the required handrail,
(iii) be terminated in a manner that will not obstruct pedestrian travel or create a hazard,
(iv) extend horizontally not less than 300 mm beyond the top and bottom of the ramp,
(v) be provided with a clearance that conforms to Sentence 3.4.6.5. (13), and
(vi) be designed and constructed such that handrails and their supports will withstand the loading values obtained from the nonconcurrent application of a concentrated load not less than 0.9 kN applied at any point and in any direction for all handrails and a uniform load not less than 0.7 kN/m applied in any direction to the handrail,
(f) except as provided in Sentence (2), have a wall or a guard on both sides and where a guard is provided the guard shall,
(i) be not less than 1 070 mm measured vertically to the top of the guard from the ramp surface, and
(ii) be designed so that no member, attachment or opening located between 140 mm and 900 mm above the ramp surface being protected by the guard will facilitate climbing,
(g) be provided,
(i) with a curb at least 50 mm high on any side of the ramp where no solid enclosure or solid guard is provided, and
(ii) with railings or other barriers that extend to within 50 mm of the finished ramp surface or have a curb not less than 50 mm high, and
(h) except as provided in Sentence (2), where the ramp is wider than 2 200 mm, have an intermediate handrail with a clear width of 900 mm between the intermediate handrail and one of the handrails described in Clause (e). (2) Where a ramp serves as an aisleway for fixed seating, the requirements for handrails in Clauses (1)(e) and (h) and for walls or guards in Clause (1)(f) need not apply. (3) Floors or walks in a barrier-free path of travel having a slope steeper than 1 in 20 shall be designed as ramps.