Div. B › Part 9 › 9.11 › 9.11.1 — Protection from Airborne Noise

9.11.1.3 — Compliance with Required Ratings

Copied!
(1) Compliance with the required STC ratings shall be demonstrated through,
(a) measurements carried out in accordance with Sentence 9.11.1.2. (1), or
(b) the construction of separating assemblies conforming to Table 1 or 2 of MMAH Supplementary Standard SB-3, “Fire and Sound Resistance of Building Assemblies”, as applicable.
(2) Compliance with the required ASTC ratings shall be demonstrated through,
(a) measurements or calculations carried out in accordance with Sentence 9.11.1.2. (2), or
(b) the construction of separating assemblies conforming to Table 1 or 2 of MMAH Supplementary Standard SB-3, “Fire and Sound Resistance of Building Assemblies”, as applicable, that have an STC rating of not less than 50 in conjunction with flanking assemblies constructed in accordance with Article 9.11.1.4.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.