(1) Exhaust ducts or vents connected to laundry-drying equipment shall discharge directly to the outdoors.
(2) Exhaust ducts connected to laundry-drying equipment shall be,
(a) independent of other exhaust ducts,
(b) accessible for cleaning, and
(c) constructed of a smooth corrosion-resistant material.
(3) Where collective venting of multiple installations of laundry-drying equipment is used, the ventilation system shall,
(a) be connected to a common exhaust duct that is vented by one central exhaust fan and incorporates one central lint trap,
(b) include an interlock to activate the central exhaust fan when laundry-drying equipment is in use, and
(c) where required by Article 9.32.3.8., be provided with make-up air.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.