Div. B › Part 9 › 9.21 › 9.21.3 — Chimney Lining

9.21.3.9 — Mortar for Chimney Liners

Copied!
(1) Chimney liners used in chimneys for solid fuel-burning appliances shall be laid in a full bed of,
(a) high temperature cement mortar conforming to CAN/CGSB-10.3, “Air Setting Refractory Mortar”, or
(b) mortar consisting of one part Portland cement to three parts sand by volume.
(2) Chimney liners used in chimneys for oil- or gas-burning appliances shall be laid in a full bed of mortar consisting of one part Portland cement to three parts sand by volume.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.