Div. B › Part 9 › 9.9 › 9.9.6 — Doors in a Means of Egress

9.9.6.2 — Clear Opening Height at Doorways

Copied!
(1) Except as provided in Sentences (2) and (3), the clear opening height of doorways shall be not less than 2 030 mm high at,
(a) exit doors,
(b) doors that open into or are located within a public corridor, and
(c) doors that open into or are located within another facility that provides access to exit from a suite.
(2) The clear opening height under door closers and other devices in doorways described in Sentence (1) shall be not less than 1 980 mm.
(3) Doorways serving a house or an individual dwelling unit need not comply with Sentences (1) and (2).
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.