Div. B › Part 9 › 9.20 › 9.20.8 — Support of Loads

9.20.8.5 — Projection of Masonry Veneer beyond Supporting Members

Copied!
(1) Masonry veneer of solid masonry units resting on a bearing support shall not project more than one-third of the thickness of the veneer.
(2) Where the masonry veneer described in Sentence (1) is rough stone masonry,
(a) the projection shall be measured as the average projection of the units, and
(b) the thickness of the veneer shall be measured as the average thickness of the veneer.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.