Div. B › Part 9 › 9.23 › 9.23.10 — Wall Studs

9.23.10.3 — Orientation of Studs

Copied!
(1) Except as permitted in Sentences (2) and (3), all studs shall be placed at right angles to the wall face.
(2) Studs on the flat are permitted to be used in gable ends of roofs that contain only unfinished space or in non-loadbearing interior walls within the limits described in Article 9.23.10.1.
(3) Wall studs that support only a load from an attic not accessible by a stairway are permitted to be placed on the flat within the limits permitted in Article 9.23.10.1. provided,
(a) the studs are clad on at least one side with plywood, OSB or waferboard sheathing fastened to the face of the studs with a structural adhesive, and
(b) the portion of the roof supported by the studs does not exceed 2.1 m in width.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.