Div. B › Part 9 › 9.15 › 9.15.3 — Footings

9.15.3.5 — Adjustments to Footing Widths for Exterior Walls

Copied!
(1) The strip footing widths for exterior walls shown in Table 9.15.3.4. shall be increased by,
(a) 65 mm for each storey of masonry veneer over wood frame construction supported by the foundation wall,
(b) 130 mm for each storey of masonry construction supported by the foundation wall, and
(c) 150 mm for each storey of flat insulating concrete form wall construction supported by the foundation wall.
Tables & Figures referenced
Table 9.15.3.4 : Minimum Footing Sizes : Forming Part of Sentence 9.15.3.4.(1)
Loading Table 9.15.3.4…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.