Div. B › Part 9 › 9.15 › 9.15.3 — Footings

9.15.3.6 — Adjustments to Footing Widths for Interior Walls

Copied!
(1) The minimum strip footing widths for interior loadbearing masonry walls shown in Table 9.15.3.4. shall be increased by 100 mm for each storey of masonry construction supported by the footing.
(2) Footings for interior non-loadbearing masonry walls shall be not less than 200 mm wide for walls up to 5.5 m high and the width shall be increased by 100 mm for each additional 2.7 m of height.
Tables & Figures referenced
Table 9.15.3.4 : Minimum Footing Sizes : Forming Part of Sentence 9.15.3.4.(1)
Loading Table 9.15.3.4…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.