(1) Hardboard shall be not less than,
(a) 3 mm thick where applied over continuous back-up,
(b) 6 mm thick where applied to supports spaced not more than 406 mm o.c., and
(c) 9 mm thick where applied to supports spaced not more than 610 mm o.c.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.