Div. B › Part 9 › 9.9 › 9.9.1 — General

9.9.1.3 — Occupant Load

Copied!
(1) The occupant load of a floor area or part of a floor area, or of a building or part of a building not having a floor area, shall be based on,
(a) two persons per sleeping room or sleeping area in a dwelling unit or suite, and
(b) for occupancies other than as described in Clause (a), the number of persons,
(i) for which the area is designed, or
(ii) determined from Table 3.1.17.1.
Tables & Figures referenced
Table 3.1.17.1 : Occupant Load : Forming Part of Article 3.1.17.1.
Loading Table 3.1.17.1…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.