Div. B › Part 9 › 9.26 › 9.26.11 — Built-Up Roofs

9.26.11.7 — Installation of Layers

Copied!
(1) In hot process applications, each layer of bitumen-saturated felt shall be laid while the bitumen is hot, with each layer overlapping the previous one.
(2) The full width under each lap referred to in Sentence (1) shall be coated with bitumen so that in no place does felt touch felt.
(3) Felt shall be laid free of wrinkles and shall be rolled directly into the hot bitumen and broomed forward and outward from the centre to ensure complete adhesion.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.