Div. B › Part 9 › 9.23 › 9.23.12 — Framing Over Openings

9.23.12.2 — Openings in Loadbearing Walls

Copied!
(1) Openings in loadbearing walls greater than the required stud spacing shall be framed with lintels designed to carry the superimposed loads to adjacent studs.
(2) Except as provided in Sentence 9.23.12.3. (2), where two or more members are used in lintels, they shall be fastened together with not less than 82 mm nails in a double row, with nails not more than 450 mm apart in each row.
(3) Lintel members may be separated by filler pieces.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.