Div. B › Part 9 › 9.23 › 9.23.10 — Wall Studs

9.23.10.7 — Stud Posts Built into Walls

Copied!
(1) Except as provided in Sentences (2) and (3), stud posts shall be designed in accordance with Part 4.
(2) The number of studs in a wall directly below a girder truss or roof beam shall conform to Tables A-34 to A-37, provided,
(a) the studs are fastened together to form a post in accordance with Sentence 9.17.4.2. (2),
(b) the wall is not less than 1.2 m long and sheathed on at least one side with plywood, OSB, waferboard or gypsum sheathing, and
(c) the wall sheathing is fastened to the stud post with at least one row of fasteners conforming to Article 9.23.3.5. and spaced not more than 150 mm o.c.
(3) The width of the stud post shall be not less than the width of the girder or beam that it supports.
Tables & Figures referenced
Table A-34 : Minimum Number of 38 × 89 mm Spruce-Pine-Fir Stud Posts in Exterior Stud Walls Supporting Girder Trusses and Roof Beams(1)(2)(3) : Forming Part of Sentence 9.23.10.7.(2)
Loading Table A-34…
Table A-37 : Minimum Number of 38 × 140 mm Northern Species Stud Posts in Exterior Stud Walls Supporting Girder Trusses and Roof Beams(1)(2)(3) : Forming Part of Sentence 9.23.10.7.(2)
Loading Table A-37…
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.