Div. B › Part 9 › 9.4 › 9.4.2 — Specified Loads

9.4.2.1 — Application

Copied!
(1) This Subsection applies to light-frame construction whose wall, floor and roof planes are generally comprised of frames of small repetitive structural members, and where,
(a) the roof and wall planes are clad, sheathed or braced on at least one side,
(b) the small repetitive structural members are spaced not more than 610 mm o.c.,
(c) the clear span of any structural member does not exceed 12.20 m,
(d) the maximum deflection of the structural roof members conforms to Article 9.4.3.1.,
(e) the maximum total roof area, notwithstanding any separation of adjoining buildings by firewalls, is 4 550 m2, and
(f) for flat roofs, there are no significant obstructions on the roof, such as parapet walls, spaced closer than the distance calculated by, Do = 10(Ho-0.8 Ss/y)
where,
Do =minimum distance between obstructions, m,
Ho =height of the obstruction above the roof, m,
Ss =ground snow load, kPa, and
y=unit weight of snow, kN/m3.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.