Div. B › Part 9 › 9.26 › 9.26.4 — Flashing at Intersections

9.26.4.7 — Intersection of Built-Up Roofs and Walls other than Masonry

Copied!
(1) The intersection of built-up roofs with walls clad with other than masonry shall have a cant strip at the intersection.
(2) The roofing membrane shall be mopped over the cant strip referred to in Sentence (1).
(3) Flashing plies shall extend not less than 150 mm up the wall referred to in Sentence (1) behind the sheathing paper.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.