Div. B › Part 9 › 9.23 › 9.23.2 — General

9.23.2.2 — Protection from Decay

Copied!
(1) Ends of wood joists, beams and other members framing into masonry or concrete shall be treated to prevent decay where the bottom of the member is at or below ground level, or a 12 mm air space shall be provided at the end and sides of the member.
(2) Air spaces required in Sentence (1) shall not be blocked by insulation, vapour barriers or air tight materials.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.