Div. B › Part 9 › 9.28 › 9.28.4 — Stucco Lath

9.28.4.5 — Application of Stucco Lath

Copied!
(1) Stucco lath shall be applied with the long dimension horizontal.
(2) Horizontal and vertical joints in stucco lath shall be lapped not less than 50 mm.
(3) End joints of stucco lath shall be staggered and shall occur over framing members.
(4) External corners of stucco lath shall be reinforced with a vertical strip of lath or reinforcing extending not less than 150 mm on both sides of the corner, or the lath or reinforcing shall extend around corners not less than 150 mm.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.