Div. B › Part 9 › 9.27 › 9.27.10 — OSB and Waferboard

9.27.10.3 — Panel Cladding

Copied!
(1) OSB and waferboard applied in panels shall have all edges supported and treated with a primer or sealer.
(2) Not less than a 3 mm gap shall be provided between sheets in cladding described in Sentence (1).
(3) Vertical joints in cladding described in Sentence (1) shall be protected with batten strips or caulking when the OSB and waferboard joints are not matched.
(4) Horizontal joints in cladding described in Sentence (1) shall be lapped not less than 25 mm or shall be suitably flashed.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.