Div. B › Part 9 › 9.28 › 9.28.4 — Stucco Lath

9.28.4.6 — Fastening

Copied!
(1) Stucco lath shall be fastened in conformance with Subsection 9.27.5.
(2) Fasteners on vertical surfaces shall be spaced not more than,
(a) 150 mm o.c. vertically and 406 mm o.c. horizontally, or
(b) 100 mm o.c. vertically and 610 mm o.c. horizontally.
(3) Nailing patterns other than those required in Sentence (2) are permitted to be used provided there are not fewer than 20 fasteners per square metre of wall surface.
(4) Fasteners on horizontal surfaces shall be spaced not more than,
(a) 150 mm o.c. along the framing members when members are spaced not more than 406 mm o.c., and
(b) 100 mm o.c. along members when members are spaced not more than 610 mm o.c.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.