Div. B › Part 9 › 9.17 › 9.17.1 — Scope

9.17.1.1 — Application

Copied!
(1) This Section applies to columns used to support,
(a) beams carrying loads from not more than 2 wood frame floors where,
(i) the supported length of joists bearing on such beams does not exceed 5 m, and
(ii) the live load on any floor does not exceed 2.4 kPa,
(b) beams or header joists carrying loads from not more than 2 levels of wood frame balconies, decks or other accessible exterior platforms, or 1 level and the roof, where,
(i) the supported length of joists bearing on such beams or joists does not exceed 5 m,
(ii) the sum of the specified snow load and the load due to use and occupancy does not exceed 4.8 kPa, and
(iii) the platform serves only a single suite of residential occupancy, or
(c) carport roofs.
(2) Columns for applications other than as described in Sentence (1) shall be designed in accordance with Part 4.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.