Div. B › Part 9 › 9.27 › 9.27.5 — Attachment of Cladding

9.27.5.3 — Furring

Copied!
(1) Except as permitted in Sentence 9.27.5.1. (4), furring for the attachment of cladding shall be not less than 19 mm by 38 mm lumber when applied over sheathing.
(2) When applied without sheathing, furring referred to in Sentence (1) shall be not less than,
(a) 19 mm by 64 mm lumber on supports spaced not more than 406 mm o.c., or
(b) 19 mm by 89 mm on supports spaced not more than 610 mm o.c.
(3) Furring referred to in Sentence (1) shall be,
(a) securely fastened to the framing, and
(b) spaced not more than 610 mm o.c.
Disclaimer. This site provides general access to Ontario Building Code information for reference only. It is not an official source and may omit or summarize content. Always verify requirements with the current OBC and your Authority Having Jurisdiction (AHJ). The Ontario Building Code is Crown copyright © King’s Printer for Ontario. Terms of Use.